What identity, purity and endotoxin tests tell you

When you review a research reagent, identify which question each test answers. A clean chromatogram, an identity measurement and an endotoxin result describe different things.

Identity: What is the material?

Ask what was compared and how selectively the method identifies the intended material. A mass measurement can support identity; a single expected mass or retention time does not necessarily distinguish closely related structures. Use the evidence your lab’s acceptance criteria require.

Purity: What does the method detect?

Check how the value was calculated. An HPLC peak-area percentage is relative to the peaks detected under that method. It is not automatically a mass fraction, the amount of reagent in the vial, or a test for every possible contaminant.

Endotoxin: What was measured, and in which units?

An endotoxin test addresses bacterial endotoxins, not sterility. Look for a result and units such as EU/mL or EU/vial, plus the reporting limit if the result is shown as less than a threshold. Don’t compare figures expressed on different bases as if they were the same.

Use criteria appropriate to your work

Do not import a limit from a different material or application. If your lab requires identity, purity and endotoxin results, record them separately and mark missing results as undocumented.